BRAND | Moore Industries |
Product | RIY-R0-4-20MA-12-42DC-DIN |
Description | RTD transmitter with display |
Internal code | IMP4178429 |
Technical specification | RIY001 tarif code 9032890 programmable isolated RTD transmitter with digital indicator input : A. all RTD sensors, 2, 3 or 4 wire according to DIN, ASA or JIS (ex. PT-100, PT-200, PT-500, PT-1000, Ni120, Cu10) B. 2 x PT-100 or 2 x PT-500 DELTA T° C. 2 or 3 x PT-100 average D. 0-4000 Ohm resistance E. FLEXOR range : all ranges possible output : 4-20mA, 2 wire current loop, load capability : 0-500 Ohm at 24 Vdc output : linear with temperature (as per RTD type) or with resistance input signal power : 12-42Vdc (max 30 Vdc with Exi use) accuracy : ± 0,05% F.S. versus actual temperature ambient temperature : -40 +82°C input and output are galvanic isolated CMR 120dB with 500 VRMS burnout protection : upscale drive standard, downscale drive is selectable equiped with integral 4 digit LCD indicator displaying the real measured input temperature |
Please Contact Us to Order to offer competitive prices and delivery time for Moore Industries - RIY-R0-4-20MA-12-42DC-DIN RTD transmitter with display number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Suomi Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
Model : IPT2/4-20MA/3-15PSIG/20PSI/-FA7 [DIN] Input : 4-20mA Output : 3-15psig Supply : 20psi Accuracy : ± 0,25% F.S. Ambient temp. range : -40 to 80°C RFI effect : 50V/m@20-1000MHz Mounting position : negligible, unit can be mounted in any position Housing : aluminium module, without mounting block *Standard complete RFI/EMI immune.
IPT2/4-20MA/3-15PSIG/20PSI/-FA1 [DIN]
IPT2 (data sheet 5.11) Input : 4-20mA Output : 3-15psig Supply : 20psi Accuracy : ± 0,25% F.S. Ambient temp. range : -40 to 80°C RFI effect : 50V/m@20-1000MHz Mounting position : negligible, unit can be mounted in any position Housing : aluminium module for DIN-rail mounting *Standard complete RFI/EMI immune. *Self-sealing connection, by mounting block and supply headers contain self-sealing valves which offers quick release and no air loss.
PWT/600AC,5A/4-20MA/1E/-50H-CE [DM]
(AC Power Transducer Manufacturer : Moore Industries Type : PWT (datasheet 15.20) Model : PWT/600AC,5A/4-20MA/1E/-50H-CE [DM] Connection : 1 element Input : 600Volt, 5 Ampere Output : 4-20mA Housing : DIN rail mounting)
PWT/600AC,5A/4-20MA/-1E-50H-240AC-CE [DM]
Connection : 1 element Input : 600Volt, 5 Ampere Output : 4-20mA Aux. power : 170 – 300Volt, ac Housing : DIN rail mounting
PWT/600AS, 5A/4-20MA/1E-50N-240AS (DM)
Measurement of active power converter PWT (input voltage (V) 600AS, input Current 5A, 4-20mA output, external power supply (V) 240AS)
SST/4-20MA/2X4-20MA/24DC/-EP [DIN]
SIL 3 Compliant Safety Signal Isolator and Splitter, 4-Wire
ELPRO COLINEAR
TELEMETRY SYSTEM SERVER,
FDY/PRG/4-20MA/12-30DC/-ISE [FL]
Frequency Converter with Display
804-030-26 - Fused Configuration USB cable
USB Configuration Cable Including Software
USB Link
HCS Hart Concentrator System
Non-Isolated Fuse Protected USB Communication Cable
Smart Hart Loop Interface and Monitor
IPX2/4-20MA/3-15PSIG/20PSI [EXIP]
Field-Mount Explosion-Proof Current-to-Pressure Transmitter
SIL 2-3 Compliant Programmable Alarm Module with Display included analog output
Programmable Alarm Module with Displayi
SAFETY RELAY MODULE
SAFETY TRIP ALARM
SPD/4-20MA/PRG/2.3VLP/-LMD [FH]
Programmable Field-Mount Loop Display
Potentiometer Transmitter