BRAND | Beamex |
Product | B9430010 / MC6-T660 |
Description | Thermostatic oven, multifunction calibrator and digital communicator |
Internal code | IMP4913063 |
Technical specification | • Temperature generation: 50/660°C • Thermal stability: up to 0.02°C • Warm-up time from 50 to 660°C: 15 minutes • Cooling time from 660 to 50°C: 35 minutes • Extended temperature uncertainty with internal sensor: up to 0.2°C • Measurement and generation of voltage, current and resistance signals • Measurement and generation of frequencies and pulses • Complete switch test • Integrated measurement loop power supply • Measurement and simulation of thermocouple signals (13 types) and temperature resistors (14 types) • Possibility to customize temperature resistors by inserting Callendar Van correction coefficients Dusen • Possibility to connect an unlimited number of interchangeable external pressure modules: measuring ranges selectable between +/- 10 mbar and 0-1000 bar, with accuracies up to +/- 0.005% f.s. + 0.01% reading. (Yes see technical bulletin for specific details for each module) • Possibility of an integrated barometric reference module, for automatic conversion of pressure measurements Relative in absolute • Total possibility of calibration and configuration of Hart instrumentation through a digital communication module optional integrated • Total possibility of calibrating and configuring FOUNDATION Fieldbus or Profibus PA instrumentation, through optional integrated digital communication module • Total documentation of the tests through integrated data memory, interfaceability to computers and software of optional CMX test management and Logical cloud software • Two simultaneous measurement channels for thermocouple measurements, with universal connection for thermocouples (connectors/mini-plug) and three channels for temperature resistors (including one for an external sample probe) • Large graphic touch screen display (5.7”) with backlight and simultaneous display of parameters in measurement and generation/simulation with multilingual user interface • 5 different operating menus on the user interface (depending on the options and modules installed): generator of temperature, calibrator, calibrator with documentation of the results, datalogger and digital communicator thorough • Dimensions and weight: 322x180x298 mm, 8.6 kg • Power supply: 230V +/ -10%, 50-60 Hz. (the multifunction calibrator section can also work on battery internal rechargeable) • Possibility to combine complete kits of external manual pumps (pneumatic and hydraulic) for generation of reference pressures • Supplied complete power cable, set of test cables and tweezers, USB cable, removal device inserts and calibration certificate issued by an accredited FINAS (EA) European Accreditation equivalent laboratory to national standards) and operating manual. • Note: For the correct operation of the instrument, the use of an MH insert is necessary |
Please Contact Us to Order to offer competitive prices and delivery time for Beamex - B9430010 / MC6-T660 Thermostatic oven, multifunction calibrator and digital communicator number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Suomi Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
field communicator
Pressure generator PGXH Workstation MCS200 calibration Four calibration field FB
Calibrator
Calibration Station
Station de travail d'étalonnage
MC-ST24; Protective Carrying Case MC2 The bag is made of durable, water and tear resistant fabric. In separate compartments there is enough space for possible accessories such as e.g .: Test leads, probes and pressure hose.
Protection bag
Protection bag
MINIMESS 1215 G 1/8 "Price
Screw coupling for high pressure Minimess 1215 G1 / 4 ''
Screw coupling for high pressure MINIMESS 1215 G1 / 4 "with the outside valve, stainless steel
Pressure gauge MINIMESS 1215 - G1 / 4 "internal, stainless steel without a valve, with O-ring
Screw coupling for high pressure MINIMESS 1215 - 1/8 NPT, Viton Seal, stainless steel with valve, with plastic cap
Screw coupling for high pressure MINIMESS 1215 - 1/4 "NPT, Viton Seal, stainless steel with valve, with plastic cap
MIC 10 DISCONTINUED/ ALTERNATIVE >>> MC2-TE
4-20mA and 0-24VDC current and voltage producing
9-channel data logger
MULTI CHANEL DATA LOGING FOR”MC5P”BENCH SYSTEM
MULTI CHANEL DATA LOGING
PRESSURE OUTPUT MODULE (MANUAL)for regulating pressure signals with high precision ,for pressure up to 20BAR
PRESSURE OUTPUT MODULE (MANUAL) for regulating pressure signals with high Precision ,for pressure up to 60BAR
low pressure pump
PGL CALIBRATION PUMP + ACCREDITED CALIBRATION CERTIFICATE
Low Pressure Calibration Pump Pressure range: -400 to 400mbar
PGM, BEAMEX-Kalibrierhandpumpe for pneumatic generation of test pressures up to 20 bar. The Vario volume used for fine adjustment; up to 0.1 mbar. About the vent valve of the pressure built up can drained finely adjusted will. A so-called. Up / Down test is perfectly possible. Pressure connections: 1/8 "NPT inside.
PGM & PGV calibration pumps, complete kit
PGXH-set, hydraulic-BEAMEX Kalibrierhandpumpenset Pressure range: 0 ... 700 bar, consisting of: PGXH, BEAMEX-Kalibrierhandpumpe hydraulic, pressure range 0 ... 700 bar. Hydraulic pump for oil, distilled water, glycol, and other liquids for generating test pressures 0 ... 700 bar. With Vario volume and drain valve for fine adjustment of the Test pressure. PGXH protective case for Kalibrierhandpumpe PGXH The ABS protective case serves to accommodate the above-mentioned Pump and offers in other Compartments accommodate high pressure measuring module EXT (sep. Pos.) Refill, High-pressure hose, fittings, small parts etc. A carrying strap allows convenient transportation at the shoulder. Dimensions: 300 x 100 x 290 mm (WxHxD). MI-S110-AA-AA-0100 High pressure hose MINIMESS 1215 DN2 PN630, 1 m long; pricked MI-2101-01-18.00 Screw coupling for high pressure MINIMESS 1215 G1 / 4 ", with cap
PM1C 9892200 obsolete / alternative B9220325 - EXT1C
PRESSURE MODULE(-1.....+1 bar g)
PRESSURE CONTROLLER COMUNICATOR FOR “MC5P” BENCH SYSTEM
PRESSURE CONTROLLER