Discover the superior quality and performance of the Inor APAQ-HRF with Impexron GMBH in Suomi . Whether you are looking for reliability or efficiency, this product meets all your industrial needs.
The APAQ-HRF is designed to provide optimal performance and durability in various applications. Known for its high-quality construction and innovative features, it is a preferred choice for professionals.
Key Features of APAQ-HRF :
At Impexron GMBH , we offer the APAQ-HRF at competitive prices and with the fastest delivery times across Suomi . Our expert team is ready to assist you with all your inquiries and provide tailored solutions to meet your specific needs.
Why Choose Impexron GMBH ?
Get Your Quote Today! Ready to enhance your operations with the APAQ-HRF ? Contact us now for a personalized quote. Fill out the form below or send us an email with your inquiry. Let us help you make a cost-effective, quality-driven choice for your business.
Important Notice: While we supply Inor products, Impexron GMBH is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
Analog Adjustable 2-wire Transmitter
for T / C J, L, T, K, N; (Analog DIN rail transmitter; not separated electrically. Span: 10 ... 50 mV Continual, fine adjustment:. ± 10%; Zero point: ± 10% of span; Output: 4-20 mA, voltage-linear; Type. Accuracy: ± 0.5 ... ± 1.0% of span; Adjustable via solder bridges and potentiometers; Default: without calibration; Weight: g 40)
70APLR0001 N0910.988909 VO342880
Pt100 3W-50/+50C
(Analog, PC-programmable, electrically. Uninsulated two-wire transmitter for Connection head assembly DIN B or greater; Pt100 input in 3-wire connection; linear with temperature; Minimum span 20 ° C; Zero adjustment: -50, -25, 0, 25, 50 ° C; Output: 4-20 mA; Default: Pt100; 3L .; 0 ... 100 ° C; Weight: 40 G)
Configuration
optional: 70CAL00002 Factory calibration/adjustment of transmitter types: APAQ
PC programmable four-wire DIN rail mount transmitter
PC-programmable two-wire transmitter for connection head assembly DIN B or greater; Galvanic isolation 1.5 kV; Input Pt100 ... Pt1000; 3- or 4-wire connection; Ni100 ... Ni1000; 11 T / C; Output: 4-20 / 20-4 mA; linear with temperature; Default: Pt100; 3L .; 0 ... 600 ° C; Weight: 40 g
PC programmable two-wire transmitter for DIN rail mounting;Inp. / Outp. galvanically isolated 1,5 kV, 11 T / C, Pt100 ... Pt1000; Ni100/Ni1000, 3 -or 4-wire connection; 4-20/20-4 mA output, linear with temperature;Factory setting: Pt100, 3L, 0 ... 600 ° C, weight: approx. 40gIncluding: 70CAL00001 - Programming / Configuration:Pt100, 4-wire connection; -20 ... +160 ° C, 4 ... 20 mA
PC-programmable two-wire transmitter for DIN rail mounting
The temperature transimitter
70APLC0001 APAQ-LC Analog Adjustable Two-Wire Transmitter for thermocouple input and 4... 20 mA output DIN Rail Mounting uncalibrated
PT100-IPAQ-L/70- I-PL00001. N11137.554587.V0571005521.
ORDER: 49,499,237. 3-L; -20..100 DEGREES
Vishay Displacement transducer Input voltage 3Vrms Linear range: 0- 100mm
STC1920ABA3530Z0000000000000 - OPTITEMP TCA-P 62 SPECIAL
(THERMOMETER *** Only Thermowell *** Type: *** OPTITEMP TCA-P 62 Special ***, Protection Tube: 1.4762 Chrome Steel - diameter: Æ 22x2,0 mm - tip design: Straight tip design Process connection: Compression Fitting G1"; 1.4404 (300 °C) Acessories: *** Stop ring ***, APPLICATION DATA Immersion Length: 1200 mm Extension Tube: 0 mm STC1920ABA3530Z0000000000000)
STC1920ABA3530Z0000000000000 - OPTITEMP TCA-P 62 SPECIAL , 1020 MM, 0MM
(THERMOMETER *** Only Thermowell *** Type: *** OPTITEMP TCA-P 62 Special ***, Protection Tube: 1.4762 Chrome Steel - diameter: Æ 22x2,0 mm - tip design: Straight tip design Process connection: Compression Fitting G1"; 1.4404 (300 °C) Acessories: *** Stop ring ***, APPLICATION DATA Immersion Length: 1020 mm Extension Tube: 0 mm STC1920ABA3530Z0000000000000)
STC1920ABA3530Z0701000000000 - OPTITEMP TCA-P 62 SPECIAL
(Connection head: AA, aluminium; Cable gland M20x1,5; Protection class IP54 Measuring insert: Mii, replaceable, spring-loaded;1x Type K (NiCr-Ni); Sensor cass 1, Temp. range type K max 1150 °C; Inconel 600 Protection tube: 1.4762 Chrome Steel - diameter: Æ 22x2,0 mm - tip design: Straight tip design Process connection: Compression Fitting G1"; 14404(300 °C) Acessories: *** Stop ring *** Immersion Length: See Application Data Connection head mount transmitter; two-wire universal transmitter - type: TT30C / - design: head mounted / - input: RTD/Thermocouple - galvanical separation: 1500 VAC, 1 min Private Label: KROHNE Standard Version,APPLICATION DATA Immersion Length: 1200 mm Extension Tube: 0 mm STC1920ABA3530Z0701000000000)
STC1920ABA3530Z0701000000000 - OPTITEMP TCA-P 62 SPECIAL, 1020 MM
(THERMOMETER Plug-In Thermocouple Type: ''' OPTITEMP TCA-P 62 Special ***, Connection head: AA, aluminium; Cable gland M20x1,5; Protection class IP54 Measuring insert: Mii, replaceable, spring-loaded;1x Type K (NiCr-Ni); Sensor cass 1, Temp. range type K max 1150 °C; Inconel 600 Protection tube: 1.4762 Chrome Steel - diameter: Æ 22x2,0 mm - tip design: Straight tip design Process connection: Compression Fitting G1"; 14404(300 °C) Acessories: *** Stop ring *** Immersion Length: See Application Data Connection head mount transmitter; two-wire universal transmitter - type: TT30C / - design: head mounted / - input: RTD/Thermocouple - galvanical separation: 1500 VAC, 1 min Private Label: KROHNE Standard Version, APPLICATION DATA Immersion Length: 1020 mm Extension Tube: 0 mm STC1920ABA3530Z0701000000000)
Isolationssignal-Splitter mit doppelten Ausgängen für mA/V Signale
PC Programmable Four-wire Transmitter
PC programmable two-wire transmitter
Order No. 70APLR0001, Type: APAQ-LR
Analog-Transmitter