38477-131   - Berthold Suomi  Sales

BRAND Berthold
Product 38477-131
Internal code IMP513379
Weight 1
Technical specification UniProbe LB 490 Level Evaluation Unit Plastic scintillator length 500mm Power supply 95 - 250 V, 50 - 60 Hz Menu controlled calibration via HART-communicator Automatic decay compensation Error indication Ambient temp: -40 to +50 - 1 analog output: 0/4 - 20 mA, isolated, passive, switchable to active - 1 digital-Input for hold-signal Relays: Max. 250VAC or 30VDC at max. 5A noninductive - 3 relays, alternative signals: hold, max / min alarm, detector temp., rad. interference - 1 failure relay 4 conduits radial 3/4" NPT Flame proof protection: ATEX II 2GD Ex d IIC T6 IP66 T 70°C flame proof protection FM/CSA: Class I, Division 1&2, Groups A, B, C, D Class II, Division 1&2, Groups E, F, G Protection: Nema 4X / IP 66 Housing: stainless steel with water cooling Customs tariff number: 90222900

Please Contact Us to Order to offer competitive prices and delivery time for Berthold - 38477-131 number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Suomi Industrial products Market. 

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

More products of Berthold

LB 491

density measurement device

LB 452 CastXpert

Radiometric Mould Level Measurement

48452-01 LB 452 castXpert

with PlugProtect plug connection

LB 6739-01 CsI 40x50

Radiometric Mould Level Measurement Sensor

LB 6739-03

(CsI 25x50 mm, with PlugProtect plug connection, scintillation counter, crystal CsI 25x50 mm, without water cooling)

LB 6739-11

GAMMAcast Detector

LB 6739-13

(CsI 25x50 mm, with PlugProtect plug connection, scintillation counter, crystal CsI 25x50 mm, with water cooling)

LB4405-16-0X-SD-E

(Rod detector: Nominal length 2000 mm Stainless steel housing with water cooling Dust Ex ATEX: II 2 D IP65 T80 ° C Operating temp .: -20 ° C ... 60 ° C)

LB 440

Level Gauge

56085-S

Vorverstärker-Board für LB 6752

PFO MARK 5 PHOTOMETER

Particle Fall Out Photometer

SYSTEM:LB-323,LB-3940 06-03269 43174.06-951/2 800859-3465 obsolete

11332014 CPU board (card) for LB-3232 monitor

Type:LB4

Detector use in LB-440-M levels in the measurement system Radioactive Source type: Co-60 source rod

LB-4401-03

Radioactive Point Detector, Temperature stability: +/- 0.1% (at -20 to +50 Celsius),Operating Temperature: -40 #. + 60 celsius, Dose Rate (μsv / h) 300 cps: 0.5

40444-21

Density Evaluation Unit (Master)

Other Category Brands

Contact us for request